I/O ports and slots | |
I/O ports and slots | 48 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASETX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 4 SFP+ 1/10GbE ports; PHY-less |
Additional ports and slots | |
Additional ports and slots | 1 dual-personality (RJ-45 or USB micro-B) serial console port |
Physical characteristics | |
Dimensions | 17.42(w) x 11.98(d) x 1.73(h) in. (44.25 x 30.42 x 4.39 cm) (1U height) |
Weight | 9.83 lb (4.46 kg) |
Memory and processor | Dual Core ARM Coretex A9 @ 1016 MHz, 1 GB DDR3 SDRAM; Packet buffer size: 12.38 MB 4.5 MB Ingress/7.875 MB Egress, 4 GB eMMC |
Performance | |
1,000 MB Latency | < 3.8 µs (64-byte packets) |
10 Gbps Latency | < 1.6 µs (64-byte packets) |
Throughput | up to 112.0 Mpps |
Switching capacity | 176 Gbps |
Routing table size | 2,000 entries (IPv4), 1,000 entries (IPv6) |
MAC address table size | 16,384 entries |
Environment | |
Operating temperature | 32°F to 113°F (0°C to 45°C); up to 5,000 Feet, -0°C to 40°C (32°F to 104°F) up to 10,000 Feet |
Operating relative humidity | 15% to 95% @ 104°F (40°C), noncondensing |
Nonoperating/Storage temperature | -40°F to 158°F (-40°C to 70°C); up to 15,000 Feet |
Nonoperating/Storage relative humidity | 15% to 95% @ 149°F (65°C) |
Acoustic | Power: 55.7 dB, Pressure: 41.7 dB |
Airflow direction | Side-to-side |
Electrical characteristics | |
Frequency | 50/60 Hz |
80plus.org Certification | Silver |
Maximum heat dissipation | 293.0 BTU/hr (309.1 kJ/hr) |
Voltage | 100–127/200–240 VAC, rated |
Current | 5.1/2.5 A |
Maximum power rating | 459 W |
Idle power | 48.6 W |
Electrical characteristics continued | |
PoE power | 370 W PoE+ |
Safety | |
Safety | UL 60950-1 2nd Edition; EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011+A2:2013; IEC 60950-1:2005 +A1:2009 +A2:2013; CSA 22.2 No. 60950-1-07 2nd; EN 60825-1:2007/IEC 60825-1:2007 Class 1 |
Emissions | |
Emissions | VCCI Class A; CNS 13438; ICES-003 Class A; FCC CFR 47 Part 15, Class A; EN 55022: 2010/CISPR-22, Class A |
Immunity | |
Generic | EN 55024:2010/CISPR 24 |
ESD | IEC 61000-4-2 |
Radiated | IEC 61000-4-3 |
EFT/Burst | IEC 61000-4-4 |
Surge | IEC 61000-4-5 |
Conducted | IEC 61000-4-6 |
Power frequency magnetic field | IEC 61000-4-8 |
Voltage dips and interruptions | IEC 61000-4-11 |
Harmonics | EN 61000-3-2, IEC 61000-3-2 |
Flicker | EN 61000-3-3, IEC 61000-3-3 |
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Liên hệ
Giá bán: | Liên hệ |